Fire door supply and fitting in England, Wales, Scotland and Northern Ireland sales@firedoor-installation.comGuide prices
Fire Door Installation

FD60 fire doors in Havant, PO9

Heavier 60-minute doors for stair cores, plant rooms and higher-risk compartment lines. Free survey in Havant and door-by-door pricing.

Quote in Havant

Free survey and a fixed written quote.

Prefer to talk? Call 0800 088 6248.

FD60 fire doors in Havant, done to the evidence

If you need FD60 fire doors in Havant, we can survey, supply and install, then leave you the evidence your fire risk assessor will ask for.

Havant has a broad mix of buildings, including small offices, light industrial buildings and houses with integral garages, and the same fire door principles apply to all of them.

Before ordering FD60 doors for a Havant building, we check the rating each opening actually needs, because over-specifying makes doors heavier and dearer. For FD60 work in Havant we generally fit certified doorsets, so frame and leaf share the same test evidence.

Why FD60 installation is less forgiving

A 54mm leaf can weigh considerably more than a 44mm one. That weight drives everything else: more robust frames and fixings, hinges rated for the load, and a closer with enough power to close and latch the door without making it too heavy to open. Glazing, if any, must use a 60-minute glass and glazing system from the same test evidence.

Because of this, most FD60 openings are best done as a certified doorset, so the frame and leaf come with matching evidence.

As standard, the work covers:

  • Frame fixing and structural gap sealing recorded with photos
  • 60-minute glazing systems where vision panels are needed
  • Load-rated hinges and correctly powered closer
  • Intumescent and smoke seals as specified

Rules and responsibilities in Havant

England's framework applies in Havant. Approved Document B guides the fire performance of new and replacement doors under the Building Regulations 2010. Day-to-day duties sit with the responsible person under the Fire Safety Order 2005, and for multi-occupied residential buildings, the Fire Safety (England) Regulations 2022 add duties such as giving residents information about fire doors.

For blocks over 11 metres in Havant, those regulations require communal fire door checks at least every three months and best-endeavours flat entrance door checks each year. In higher-risk buildings, building work is overseen by the Building Safety Regulator, so we check whether approval is needed before starting.

Who needs FD60 fire doors in Havant?

The need for FD60 fire doors usually arises in plant and boiler rooms or mixed-use commercial buildings, and sometimes stair cores in taller blocks. Each has its own pressures, such as residents at home or a building that must stay open, so we plan the sequence of work in Havant to keep escape routes protected throughout.

Our process in Havant

  1. Confirm the 60-minute requirement against the fire strategy
  2. Survey structure, opening size and wall type
  3. Order the certified doorset with ironmongery to its evidence
  4. Install the frame, fix and seal it to the structure
  5. Hang, adjust and test the leaf, closer and latching
  6. Record evidence and make good

What does FD60 fire doors cost in Havant?

As a guide, budget £850–£1,800 per FD60 doorset supplied and fitted, ex VAT for FD60 fire doors. The figure for your Havant building depends on the number of doors, the rating, the condition of the frames, finishes, hardware and access. We confirm a fixed price after the free survey.

Havant and neighbouring towns

Havant is about 29.8 km from Southampton, and we cover both, along with nearby Waterlooville and Portsmouth. Send us your postcode and we'll confirm survey dates.

Common questions

Is Havant within your coverage area?

It is. We cover Havant in Hampshire and neighbouring towns such as Waterlooville. There is no charge for the survey.

Can you work from an existing inspection report for my Havant building?

Yes. Send it over and we can often price straight from it, then confirm on site. We report back against the same door references so you can close actions off.

Can I upgrade an FD30 door to FD60?

Not by adding parts. An FD30 leaf cannot be turned into an FD60 door with extra strips or paint. If an opening needs 60 minutes, the leaf, and usually the frame, need to be replaced with a certified FD60 product.

Is FD60 just a thicker FD30?

No. FD60 doors are built and tested as a different product, usually with a thicker core, different seals and different ironmongery. Only the tested combination carries the 60-minute rating.

Talk to us about Havant

Tell us about the doors and we will come back with survey dates and a fixed written quote.

CallGet a quote