Fire door supply and fitting in England, Wales, Scotland and Northern Ireland sales@firedoor-installation.comGuide prices
Fire Door Installation

FD60 fire doors in Eastbourne

Surveyed, supplied and fitted in Eastbourne. Heavier 60-minute doors for stair cores, plant rooms and higher-risk compartment lines.

Quote in Eastbourne

Free survey and a fixed written quote.

Prefer to talk? Call 0800 088 6248.

FD60 fire doors in Eastbourne, done to the evidence

From the BN21 postcode district outwards, we take on FD60 fire doors across Eastbourne for homes, blocks and workplaces.

In and around Eastbourne, fire door work covers everything from care homes to purpose-built flats. We plan each job around the people who use the building.

FD60 openings in Eastbourne buildings tend to be stair cores, plant rooms and bin stores in larger blocks and commercial premises. For FD60 work in Eastbourne we generally fit certified doorsets, so frame and leaf share the same test evidence.

Why FD60 installation is less forgiving

A 54mm leaf can weigh considerably more than a 44mm one. That weight drives everything else: more robust frames and fixings, hinges rated for the load, and a closer with enough power to close and latch the door without making it too heavy to open. Glazing, if any, must use a 60-minute glass and glazing system from the same test evidence.

Because of this, most FD60 openings are best done as a certified doorset, so the frame and leaf come with matching evidence.

Each installation includes:

  • 60-minute glazing systems where vision panels are needed
  • Load-rated hinges and correctly powered closer
  • Certified FD60 doorset or leaf with matching evidence
  • Check of the fire strategy rating for each opening

The regulations behind fire doors in Eastbourne

In Eastbourne, as elsewhere in England, the starting point is the Fire Safety Order 2005: whoever controls a workplace or the shared parts of a residential block must make sure its fire doors work. When doors are replaced, the Building Regulations and Approved Document B set the standard the new work has to meet.

Blocks above 11 metres have a specific routine under regulation 10 of the Fire Safety (England) Regulations 2022: quarterly checks of communal fire doors and annual best-endeavours checks of flat front doors. If your Eastbourne building is a higher-risk building under the Building Safety Act 2022, we confirm the approval route with the Principal Accountable Person before any work is ordered.

Who needs FD60 fire doors in Eastbourne?

Landlords, managing agents, facilities teams and homeowners in Eastbourne can all commission FD60 fire doors from us. The usual settings are stair cores in taller blocks and refuse stores, though single doors for plant and boiler rooms are just as welcome.

What happens after you enquire

  1. Confirm the 60-minute requirement against the fire strategy
  2. Survey structure, opening size and wall type
  3. Order the certified doorset with ironmongery to its evidence
  4. Install the frame, fix and seal it to the structure
  5. Hang, adjust and test the leaf, closer and latching
  6. Record evidence and make good

What does FD60 fire doors cost in Eastbourne?

As a guide, budget £850–£1,800 per FD60 doorset supplied and fitted, ex VAT for FD60 fire doors. The figure for your Eastbourne building depends on the number of doors, the rating, the condition of the frames, finishes, hardware and access. We confirm a fixed price after the free survey.

Around Eastbourne

Eastbourne is about 30.5 km from Brighton, and we cover both, along with nearby Hailsham and Seaford. Send us your postcode and we'll confirm survey dates.

Common questions

Do you work in Eastbourne?

Yes, we take on FD60 fire doors in Eastbourne and the surrounding area, including Hailsham and Seaford. Send your postcode and a few details and we'll come back with survey dates.

How quickly can you survey in Eastbourne?

It depends on the number of doors and access, but we offer survey dates as soon as we reply to your enquiry. If an inspection has found urgent safety issues, tell us and we'll prioritise.

Do FD60 doors need smoke seals?

If the fire strategy asks for smoke control, yes: the door will be specified as FD60S or E60Sa with smoke seals. Many plant room doors are FD60 without a smoke requirement.

Can I upgrade an FD30 door to FD60?

Not by adding parts. An FD30 leaf cannot be turned into an FD60 door with extra strips or paint. If an opening needs 60 minutes, the leaf, and usually the frame, need to be replaced with a certified FD60 product.

Book a free survey in Eastbourne

Tell us about the doors and we will come back with survey dates and a fixed written quote.

CallGet a quote