FD60 fire doors in Hove: what's involved
If you need FD60 fire doors in Hove, we can survey, supply and install, then leave you the evidence your fire risk assessor will ask for.
Around Hove, HMOs, family homes after loft conversions and high-street shops all depend on fire doors that close, latch and seal. We survey each opening and tell you plainly which doors need work and which don't.
FD60 openings in Hove buildings tend to be stair cores, plant rooms and bin stores in larger blocks and commercial premises. Before ordering FD60 doors for a Hove building, we check the rating each opening actually needs, because over-specifying makes doors heavier and dearer.
What do you hand over at the end?
For every FD60 opening we record the product and certificate reference, the gap measurements, the hinge and closer specification, how the frame was fixed and what was used to seal the frame-to-structure gap, with photographs before the architraves go on. That record is what your fire risk assessor or building control officer will ask for.
What you get:
- Check of the fire strategy rating for each opening
- Frame fixing and structural gap sealing recorded with photos
- Intumescent and smoke seals as specified
- 60-minute glazing systems where vision panels are needed
Which fire door rules apply in Hove?
Fire doors in Hove fall under English rules. New and replacement doors are covered by the Building Regulations 2010 and Approved Document B. In workplaces and the common parts of blocks, the Regulatory Reform (Fire Safety) Order 2005, as clarified by the Fire Safety Act 2021, puts the duty on the responsible person to keep fire doors suitable and maintained.
For residential buildings in Hove above 11 metres, regulation 10 of the Fire Safety (England) Regulations 2022 adds checks: communal fire doors at least every three months and best-endeavours checks of flat entrance doors at least every twelve months. Higher-risk buildings of at least 18 metres or seven storeys also come under the Building Safety Act 2022, where works may need approval from the Building Safety Regulator.
Who needs FD60 fire doors in Hove?
The need for FD60 fire doors usually arises in plant and boiler rooms or mixed-use commercial buildings, and sometimes stair cores in taller blocks. Each has its own pressures, such as residents at home or a building that must stay open, so we plan the sequence of work in Hove to keep escape routes protected throughout.
From enquiry to handover in Hove
- Confirm the 60-minute requirement against the fire strategy
- Survey structure, opening size and wall type
- Order the certified doorset with ironmongery to its evidence
- Install the frame, fix and seal it to the structure
- Hang, adjust and test the leaf, closer and latching
- Record evidence and make good
Prices for FD60 fire doors in Hove
As a guide, budget £850–£1,800 per FD60 doorset supplied and fitted, ex VAT for FD60 fire doors. The figure for your Hove building depends on the number of doors, the rating, the condition of the frames, finishes, hardware and access. We confirm a fixed price after the free survey.
Covering Hove and nearby
We also cover towns near Hove, including Brighton (2.0 km away), Portslade and Rottingdean. If your building is in BN3 or a neighbouring district, the service and pricing are the same.
Questions
Do you cover BN3 and nearby postcodes?
Yes. We cover Hove including BN3, and nearby towns such as Brighton and Portslade. The survey and written quote are free.
What happens on a survey in Hove?
We look at every door in scope: the leaf, frame, gaps, seals, hinges, closer, glazing and how the frame is fixed. You then get a written quote that prices each door separately.
Do FD60 doors need smoke seals?
If the fire strategy asks for smoke control, yes: the door will be specified as FD60S or E60Sa with smoke seals. Many plant room doors are FD60 without a smoke requirement.
Can I upgrade an FD30 door to FD60?
Not by adding parts. An FD30 leaf cannot be turned into an FD60 door with extra strips or paint. If an opening needs 60 minutes, the leaf, and usually the frame, need to be replaced with a certified FD60 product.