Fire door supply and fitting in England, Wales, Scotland and Northern Ireland sales@firedoor-installation.comGuide prices
Fire Door Installation

FD30 fire doors in Ipswich

Surveyed, supplied and fitted in Ipswich. The everyday 30-minute fire door, supplied as a leaf or full doorset and fitted to its evidence.

Quote in Ipswich

Free survey and a fixed written quote.

Prefer to talk? Call 0800 088 6248.

FD30 fire doors: our service in Ipswich

Looking for FD30 fire doors in Ipswich? We supply and fit certified fire doors and components across Ipswich and the wider Suffolk area, working from a free survey and a fixed written quote.

Fire doors in Ipswich protect escape routes in GP surgeries, care homes and offices alike. We adapt the programme to the building and its occupants, never the standard of the installation.

In Ipswich, FD30 doors are the usual choice for escape-route corridors, stairs and kitchen doors where the fire strategy asks for 30 minutes. For a mixed portfolio in Ipswich, we can survey every FD30 opening in one visit and price leaf-only and doorset options side by side.

What does a correct FD30 installation include?

A typical timber FD30 leaf is around 44mm thick and hangs on at least three fire-tested hinges. The gaps between leaf and frame are set to the manufacturer's data, usually around 3mm. Intumescent strips, and smoke seals where needed, go in the frame or leaf edge as specified. The closer must pull the door shut and latch it from any angle. Every hole cut for a lock, latch or hinge is lined with intumescent material where the certification calls for it.

Then comes the part that is often skipped: sealing the gap between the frame and the wall with a tested material, as BS 8214:2026 now sets out in more detail.

As standard, the work covers:

  • Overhead closer set to close and latch
  • Photo record, product data and certificate references at handover
  • Certified FD30 or FD30S leaf, or full doorset
  • Survey of the opening, frame and existing ironmongery

Fire door law for Ipswich properties

The rules that apply to fire doors in Ipswich are England's. The responsible person under the Regulatory Reform (Fire Safety) Order 2005 must keep fire doors in non-domestic premises and the common parts of flats in working order; the Fire Safety Act 2021 confirmed that this includes flat entrance doors onto common parts.

Where a Ipswich block is above 11 metres, regulation 10 of the 2022 regulations means communal doors are checked every three months and flat entrance doors annually on a best-endeavours basis. Replacement doors must also satisfy the Building Regulations, with Approved Document B as the guidance most building control bodies work from.

Who needs FD30 fire doors in Ipswich?

From care homes to schools, the requirement for FD30 fire doors in Ipswich comes from the fire strategy or risk assessment for the building. We work from that document, or help you interpret your inspection report, before quoting.

The steps on a Ipswich installation

  1. Measure the opening, check the frame and confirm the rating needed
  2. Order a certified leaf or doorset to size, with matching components
  3. Remove the old door and assess the frame or structural opening
  4. Fix the frame and hang the leaf to the certified gap tolerances
  5. Fit seals, hinges, latch, closer and signage, then test close-and-latch
  6. Seal the frame-to-wall gap, make good and record the evidence

What does FD30 fire doors cost in Ipswich?

If you need a budget figure first, the guide for FD30 fire doors is £300–£600 for a leaf into a sound existing frame; £650–£1,300 for a doorset, ex VAT. We firm that up after a survey, pricing each door separately so you can see where the money goes.

Covering Ipswich and nearby

As well as Ipswich, we cover neighbouring towns including Harwich, Felixstowe and Stowmarket. The survey and quote are free.

Common questions

Do you work in Ipswich?

Yes, we take on FD30 fire doors in Ipswich and the surrounding area, including Harwich and Felixstowe. Send your postcode and a few details and we'll come back with survey dates.

Do I need to be there for the survey?

Someone needs to give us access to the doors. For blocks and commercial buildings, a caretaker or site contact is fine; for HMOs and homes, we agree a time with you or your tenants.

Do FD30 doors need a closer?

Most do. Doors on escape routes, flat entrance doors and doors in the common parts of buildings need a self-closing device that shuts and latches the door. Some doors inside houses and locked riser doors are exceptions, depending on the fire strategy.

Can a new FD30 door go into my old frame?

Sometimes. The frame has to be sound, square, securely fixed and compatible with the new leaf's certification. Many older frames are not, especially softwood linings or frames altered for previous doors. We check each frame on the survey and recommend a doorset only where the frame cannot be relied on.

Talk to us about Ipswich

Tell us about the doors and we will come back with survey dates and a fixed written quote.

CallGet a quote