FD30 fire doors in Chatham, done to the evidence
From the ME4 postcode district outwards, we take on FD30 fire doors across Chatham for homes, blocks and workplaces.
In and around Chatham, fire door work covers everything from houses with integral garages to low-rise blocks of flats. We plan each job around the people who use the building.
Each FD30 leaf we supply for Chatham is sized for the opening, rather than trimmed beyond what its certification allows. In Chatham, FD30 doors are the usual choice for escape-route corridors, stairs and kitchen doors where the fire strategy asks for 30 minutes.
Leaf only or a full doorset?
If the existing frame is sound, correctly sized, securely fixed and compatible with the new leaf's certification, a new FD30 leaf can be hung in it. Many frames do not pass that test: old softwood linings, frames that have been cut about for previous doors, or frames with no evidence of how they were fixed. In those cases a certified doorset (leaf, frame and ironmongery tested together) is the cleaner answer and usually the quicker one on site.
We tell you which route each opening needs on the survey, door by door, and why.
What you get:
- Fire-tested hinges, latch or lock and intumescent pads
- Survey of the opening, frame and existing ironmongery
- Photo record, product data and certificate references at handover
- Frame-to-wall gap sealed with an evidenced material
What the rules say for Chatham
The rules that apply to fire doors in Chatham are England's. The responsible person under the Regulatory Reform (Fire Safety) Order 2005 must keep fire doors in non-domestic premises and the common parts of flats in working order; the Fire Safety Act 2021 confirmed that this includes flat entrance doors onto common parts.
Where a Chatham block is above 11 metres, regulation 10 of the 2022 regulations means communal doors are checked every three months and flat entrance doors annually on a best-endeavours basis. Replacement doors must also satisfy the Building Regulations, with Approved Document B as the guidance most building control bodies work from.
Which buildings in Chatham need FD30 fire doors?
Typical settings for FD30 fire doors include schools, blocks of flats and care homes. In Chatham, as anywhere, the duty holder varies: a responsible person for a workplace, a landlord or managing agent for a block or HMO, or a homeowner after building work. We adjust access, timing and paperwork to suit whoever commissions the work.
Our process in Chatham
- Measure the opening, check the frame and confirm the rating needed
- Order a certified leaf or doorset to size, with matching components
- Remove the old door and assess the frame or structural opening
- Fix the frame and hang the leaf to the certified gap tolerances
- Fit seals, hinges, latch, closer and signage, then test close-and-latch
- Seal the frame-to-wall gap, make good and record the evidence
What does FD30 fire doors cost in Chatham?
If you need a budget figure first, the guide for FD30 fire doors is £300–£600 for a leaf into a sound existing frame; £650–£1,300 for a doorset, ex VAT. We firm that up after a survey, pricing each door separately so you can see where the money goes.
Covering Chatham and nearby
We also cover towns near Chatham, including Rochester (1.8 km away), Gillingham and Strood. If your building is in ME4 or a neighbouring district, the service and pricing are the same.
Common questions
Is Chatham within your coverage area?
It is. We cover Chatham in Kent and neighbouring towns such as Rochester. There is no charge for the survey.
Can you work from an existing inspection report for my Chatham building?
Yes. Send it over and we can often price straight from it, then confirm on site. We report back against the same door references so you can close actions off.
Do FD30 doors need a closer?
Most do. Doors on escape routes, flat entrance doors and doors in the common parts of buildings need a self-closing device that shuts and latches the door. Some doors inside houses and locked riser doors are exceptions, depending on the fire strategy.
What is the difference between FD30 and FD30S?
FD30S has been tested for smoke control as well as fire. It adds a smoke seal, usually a brush or blade, and needs a tight threshold gap. Flat entrance doors and doors onto protected escape routes are commonly specified as FD30S.