Fire door supply and fitting in England, Wales, Scotland and Northern Ireland sales@firedoor-installation.comGuide prices
Fire Door Installation

Loft conversion fire doors in Christchurch, BH6

Fire doors onto the protected stair when a loft conversion adds a new storey. Free survey in Christchurch and door-by-door pricing.

Quote in Christchurch

Free survey and a fixed written quote.

Prefer to talk? Call 0800 088 6248.

Getting loft conversion fire doors right in Christchurch

If you need loft conversion fire doors in Christchurch, we can survey, supply and install, then leave you the evidence your fire risk assessor will ask for.

Christchurch has a broad mix of buildings, including schools, small blocks of flats and light industrial buildings, and the same fire door principles apply to all of them.

We can fit loft conversion fire doors in Christchurch as your builder's subcontractor or directly for you. For homes in Christchurch, we match fire doors to your existing style wherever certified options allow.

FD20 or FD30?

In England, the guidance generally asks for FD20 (E20) doors in this situation, and self-closers are not usually required within a house. Scotland is different: the domestic Technical Handbook expects doors onto the protected stair enclosure to be self-closing fire doors, so closers are part of the job there. Many homeowners choose FD30 doors anyway, because they are widely available and the price difference is small. Either way, the door must be fitted properly: correct gaps, fire-tested hinges and an intumescent strip where the product requires one.

As standard, the work covers:

  • Frame repairs or new linings where needed
  • Check of which openings need fire doors
  • Fire-tested hinges and intumescent strips as required
  • Work coordinated with your builder

The regulations behind fire doors in Christchurch

The rules that apply to fire doors in Christchurch are England's. The responsible person under the Regulatory Reform (Fire Safety) Order 2005 must keep fire doors in non-domestic premises and the common parts of flats in working order; the Fire Safety Act 2021 confirmed that this includes flat entrance doors onto common parts.

Where a Christchurch block is above 11 metres, regulation 10 of the 2022 regulations means communal doors are checked every three months and flat entrance doors annually on a best-endeavours basis. Replacement doors must also satisfy the Building Regulations, with Approved Document B as the guidance most building control bodies work from.

Buildings and duty holders in Christchurch

Typical settings for loft conversion fire doors include semi-detached houses, terraced houses and detached family homes. In Christchurch, as elsewhere, the work is usually commissioned by homeowners, often alongside a builder or after a building control visit, so we fit around the household and leave the product details building control asks for.

The steps on a Christchurch installation

  1. Review the building control requirements or drawings
  2. Survey each door opening off the stair
  3. Agree door style and rating
  4. Fit doors, hinges and strips
  5. Check gaps and operation
  6. Hand over product details

Budgeting for loft conversion fire doors in Christchurch

As a guide, budget £300–£650 per door supplied and fitted, ex VAT for loft conversion fire doors. The figure for your Christchurch building depends on the number of doors, the rating, the condition of the frames, finishes, hardware and access. We confirm a fixed price after the free survey.

Christchurch and neighbouring towns

Neighbouring towns such as Bournemouth, New Milton, Poole and Totton are covered too, so clients with several buildings can use one installer and one evidence format.

Questions from Christchurch

Do you cover BH6 and nearby postcodes?

Yes. We cover Christchurch including BH6, and nearby towns such as Bournemouth and New Milton. The survey and written quote are free.

Can you work from an existing inspection report for my Christchurch building?

Yes. Send it over and we can often price straight from it, then confirm on site. We report back against the same door references so you can close actions off.

Do loft conversion fire doors need closers?

Not usually within a single-family house in England. In Scotland, doors onto the protected stair enclosure are expected to be self-closing. Wales and Northern Ireland have their own guidance, and your building control body may ask for something different in particular layouts.

Do all my doors need to be fire doors after a loft conversion?

Usually the doors from habitable rooms onto the stair do, on every floor. Bathrooms are often excluded. Building control decides for your house.

More loft conversion fire doors in Dorset

Book a free survey in Christchurch

Tell us about the doors and we will come back with survey dates and a fixed written quote.

CallGet a quote