FD30 fire doors: our service in Newry
For property owners, landlords and managing agents in Newry, we offer FD30 fire doors with one team for the survey, the product and the installation.
Around Newry, houses with integral garages, family homes after loft conversions and schools all depend on fire doors that close, latch and seal. We survey each opening and tell you plainly which doors need work and which don't.
In Newry, FD30 doors are the usual choice for escape-route corridors, stairs and kitchen doors where the fire strategy asks for 30 minutes. Each FD30 leaf we supply for Newry is sized for the opening, rather than trimmed beyond what its certification allows.
Where are FD30 doors used?
FD30 is the rating most buildings rely on. You will find it on flat entrance doors, doors onto escape corridors and stairs in houses in multiple occupation, kitchen doors in HMOs, and most internal doors on escape routes in offices, schools, surgeries and shops. Where smoke control matters too, the door is specified as FD30S (E30Sa), which adds a smoke seal and a tighter threshold.
The rating your building needs comes from its fire strategy or fire risk assessment, not from the door supplier. If you are unsure whether a door should be FD30 or FD60, we check the drawings, the risk assessment and what is installed now before we price anything. Our FD30 vs FD60 guide explains the difference.
Each installation includes:
- Survey of the opening, frame and existing ironmongery
- Certified FD30 or FD30S leaf, or full doorset
- Overhead closer set to close and latch
- Intumescent strips and smoke seals to the certification
Fire door law for Newry properties
Newry is in Northern Ireland, where fire doors are covered by the Building Regulations (Northern Ireland) 2012 and Technical Booklet E on fire safety. Duties in non-domestic premises come from the Fire and Rescue Services (Northern Ireland) Order 2006 and the Fire Safety Regulations (Northern Ireland) 2010.
The English regulation 10 checking regime does not apply here, so the fire risk assessment sets how often doors in Newry are checked. We hand over evidence that supports it.
Buildings and duty holders in Newry
You are most likely to need FD30 fire doors if you look after blocks of flats, offices or shops. Whatever the building in Newry, we survey each opening and tell you which doors need work and which do not.
The steps on a Newry installation
- Measure the opening, check the frame and confirm the rating needed
- Order a certified leaf or doorset to size, with matching components
- Remove the old door and assess the frame or structural opening
- Fix the frame and hang the leaf to the certified gap tolerances
- Fit seals, hinges, latch, closer and signage, then test close-and-latch
- Seal the frame-to-wall gap, make good and record the evidence
Prices for FD30 fire doors in Newry
If you need a budget figure first, the guide for FD30 fire doors is £300–£600 for a leaf into a sound existing frame; £650–£1,300 for a doorset, ex VAT. We firm that up after a survey, pricing each door separately so you can see where the money goes.
Around Newry
Newry is about 68.9 km from Bangor, and we cover both, along with nearby Portadown and Craigavon. Send us your postcode and we'll confirm survey dates.
Questions from Newry
Do you cover BT35 and nearby postcodes?
Yes. We cover Newry including BT35, and nearby towns such as Portadown and Craigavon. The survey and written quote are free.
How quickly can you survey in Newry?
It depends on the number of doors and access, but we offer survey dates as soon as we reply to your enquiry. If an inspection has found urgent safety issues, tell us and we'll prioritise.
How long does it take to fit an FD30 door?
A leaf into a sound frame is often a few hours. A full doorset including frame removal, fixing, sealing and making good is usually half a day to a day per opening, depending on access and the wall construction.
What is the difference between FD30 and FD30S?
FD30S has been tested for smoke control as well as fire. It adds a smoke seal, usually a brush or blade, and needs a tight threshold gap. Flat entrance doors and doors onto protected escape routes are commonly specified as FD30S.

