Fire door supply and fitting in England, Wales, Scotland and Northern Ireland sales@firedoor-installation.comGuide prices
Fire Door Installation

FD60 fire doors in Glasgow

Heavier 60-minute doors for stair cores, plant rooms and higher-risk compartment lines. Available throughout Glasgow, with a free survey and fixed written quote.

Quote for Glasgow

Free survey and a fixed written quote.

Prefer to talk? Call 0800 088 6248.

FD60 fire doors in Glasgow: what's involved

We provide FD60 fire doors across Glasgow, covering 28 postcode districts from G1 to G69.

FD60 openings in Glasgow buildings tend to be stair cores, plant rooms and bin stores in larger blocks and commercial premises. Before ordering FD60 doors for a Glasgow building, we check the rating each opening actually needs, because over-specifying makes doors heavier and dearer.

Fire door work in Glasgow spans housing providers with large estates, individual landlords, businesses and homeowners. We price every job from a survey, never from a list price alone, because the condition of the frames and the hardware makes a real difference.

When does a building need FD60 rather than FD30?

FD60 doors appear where the fire strategy asks a wall to resist fire for an hour: stair cores and lobbies in taller buildings, plant and boiler rooms, some service risers, refuse stores and compartment walls between different uses. The rating follows the wall. Fitting an FD30 door in a 60-minute wall leaves a weak point, and fitting FD60 everywhere wastes money and makes doors harder to open.

We work from your fire strategy, the building's drawings or the fire risk assessment. Where these disagree with what is on site, we flag it before ordering.

The regulations behind fire doors in Glasgow

In Glasgow, fire doors are specified against Scotland's Technical Handbooks (Section 2: Fire) under the Building (Scotland) Regulations 2004, rather than Approved Document B. Duties in non-domestic premises come from the Fire (Scotland) Act 2005 and the Fire Safety (Scotland) Regulations 2006.

England's regulation 10 does not apply in Scotland. We follow the building's fire risk assessment and, where building work needs a warrant, the local authority's requirements.

Our process in Glasgow

  1. Confirm the 60-minute requirement against the fire strategy
  2. Survey structure, opening size and wall type
  3. Order the certified doorset with ironmongery to its evidence
  4. Install the frame, fix and seal it to the structure
  5. Hang, adjust and test the leaf, closer and latching
  6. Record evidence and make good

What does FD60 fire doors cost in Glasgow?

Budget around £850–£1,800 per FD60 doorset supplied and fitted, ex VAT for FD60 fire doors. Our guide prices are the same in Glasgow as elsewhere; what changes the cost is the doors themselves. Use our guide-price tool for a quick estimate.

FD60 fire doors questions

Do you provide FD60 fire doors across Glasgow?

Yes. We cover all of Glasgow. Surveys and written quotes are free.

Do FD60 doors need smoke seals?

If the fire strategy asks for smoke control, yes: the door will be specified as FD60S or E60Sa with smoke seals. Many plant room doors are FD60 without a smoke requirement.

Is FD60 just a thicker FD30?

No. FD60 doors are built and tested as a different product, usually with a thicker core, different seals and different ironmongery. Only the tested combination carries the 60-minute rating.

FD60 fire doors by town in Glasgow

Book a free survey in Glasgow

Tell us about the doors and we will come back with survey dates and a fixed written quote.

CallGet a quote