Fire door supply and fitting in England, Wales, Scotland and Northern Ireland sales@firedoor-installation.comGuide prices
Fire Door Installation

Double fire door installation in Halesowen

Pairs and leaf-and-a-half doorsets with meeting-edge seals, coordinators and flush bolts. Covering Halesowen and B63, with a free survey and fixed written quote.

Quote in Halesowen

Free survey and a fixed written quote.

Prefer to talk? Call 0800 088 6248.

Double fire doors in Halesowen: what's involved

From the B63 postcode district outwards, we take on double fire doors across Halesowen for homes, blocks and workplaces.

Buildings in and around Halesowen range from high-street shops to family homes after loft conversions and low-rise blocks of flats. Whatever the building, the standard is the same: certified products, correct gaps, seals and closers, and a frame sealed to the wall.

Leaf-and-a-half doors are a practical option for Halesowen care homes and schools that need occasional wide access. Double doors on wards, school corridors and lobbies in Halesowen take heavy use, so closing sequence and meeting-edge seals get extra attention.

Leaf-and-a-half for wider routes

Leaf-and-a-half doors give a usable everyday opening through the main leaf, with the smaller leaf opened for beds, trolleys or deliveries. They are common in care homes, hospitals and schools. The smaller leaf may be held with flush bolts; any bolts and their positions must be covered by the evidence.

As standard, the work covers:

  • Equal pair or leaf-and-a-half doorsets
  • Flush bolts and hold-opens within evidence
  • Closers matched to each leaf
  • Meeting-stile intumescent and smoke seals

Which fire door rules apply in Halesowen?

In Halesowen, as elsewhere in England, the starting point is the Fire Safety Order 2005: whoever controls a workplace or the shared parts of a residential block must make sure its fire doors work. When doors are replaced, the Building Regulations and Approved Document B set the standard the new work has to meet.

Blocks above 11 metres have a specific routine under regulation 10 of the Fire Safety (England) Regulations 2022: quarterly checks of communal fire doors and annual best-endeavours checks of flat front doors. If your Halesowen building is a higher-risk building under the Building Safety Act 2022, we confirm the approval route with the Principal Accountable Person before any work is ordered.

Which buildings in Halesowen need double fire doors?

The need for double fire doors usually arises in care homes or schools, and sometimes communal corridors. Each has its own pressures, such as residents at home or a building that must stay open, so we plan the sequence of work in Halesowen to keep escape routes protected throughout.

From enquiry to handover in Halesowen

  1. Survey opening width, use and traffic
  2. Select pair configuration and hardware set
  3. Order certified doorset with coordinator and bolts if needed
  4. Install frame and hang both leaves
  5. Set closing sequence, seals and latching
  6. Test hold-open release and record evidence

Budgeting for double fire doors in Halesowen

As a guide, budget £1,600–£3,400 per pair supplied and fitted, depending on glazing and hardware, ex VAT for double fire doors. The figure for your Halesowen building depends on the number of doors, the rating, the condition of the frames, finishes, hardware and access. We confirm a fixed price after the free survey.

Covering Halesowen and nearby

We also cover towns near Halesowen, including Bartley Green (3.8 km away), Brierley Hill and Dudley. If your building is in B63 or a neighbouring district, the service and pricing are the same.

Questions from Halesowen

Is Halesowen within your coverage area?

It is. We cover Halesowen in West Midlands and neighbouring towns such as Bartley Green. There is no charge for the survey.

Can you work from an existing inspection report for my Halesowen building?

Yes. Send it over and we can often price straight from it, then confirm on site. We report back against the same door references so you can close actions off.

Can double fire doors be held open?

Yes, with hold-open devices that release on the fire alarm, or with free-swing closers. Wedges and hooks are not acceptable.

Why does the gap between the two leaves matter?

The meeting edges are where flame and smoke can pass most easily. The gap and the seals there must match the certification for the pair to perform as tested.

Talk to us about Halesowen

Tell us about the doors and we will come back with survey dates and a fixed written quote.

CallGet a quote