Fire door supply and fitting in England, Wales, Scotland and Northern Ireland sales@firedoor-installation.comGuide prices
Fire Door Installation

Double fire door installation in Eltham

Surveyed, supplied and fitted in Eltham. Pairs and leaf-and-a-half doorsets with meeting-edge seals, coordinators and flush bolts.

Quote in Eltham

Free survey and a fixed written quote.

Prefer to talk? Call 0800 088 6248.

Double fire doors for Eltham buildings

If you need double fire doors in Eltham, we can survey, supply and install, then leave you the evidence your fire risk assessor will ask for.

Fire doors in Eltham protect escape routes in shared houses, purpose-built blocks of flats and student accommodation alike. We adapt the programme to the building and its occupants, never the standard of the installation.

Leaf-and-a-half doors are a practical option for Eltham care homes and schools that need occasional wide access. Double doors on wards, school corridors and lobbies in Eltham take heavy use, so closing sequence and meeting-edge seals get extra attention.

Why pairs need extra care

The meeting stiles are the weak point of a pair. Gaps there must be controlled, both leaves need intumescent and smoke seals as specified, and if the meeting edges are rebated, a door coordinator is usually needed so the leaves close in the right order. If they close out of sequence, the door may not latch and will not perform as tested.

As standard, the work covers:

  • Closers matched to each leaf
  • Meeting-stile intumescent and smoke seals
  • Commissioning of closing sequence
  • Door coordinators where meeting edges are rebated

Rules and responsibilities in Eltham

Fire doors in Eltham fall under English rules. New and replacement doors are covered by the Building Regulations 2010 and Approved Document B. In workplaces and the common parts of blocks, the Regulatory Reform (Fire Safety) Order 2005, as clarified by the Fire Safety Act 2021, puts the duty on the responsible person to keep fire doors suitable and maintained. Enforcement of fire safety law in Eltham sits with the London Fire Brigade.

For residential buildings in Eltham above 11 metres, regulation 10 of the Fire Safety (England) Regulations 2022 adds checks: communal fire doors at least every three months and best-endeavours checks of flat entrance doors at least every twelve months. Higher-risk buildings of at least 18 metres or seven storeys also come under the Building Safety Act 2022, where works may need approval from the Building Safety Regulator.

Who needs double fire doors in Eltham?

Typical settings for double fire doors include schools, office cores and hospitals and clinics. In Eltham, as anywhere, the duty holder varies: a responsible person for a workplace, a landlord or managing agent for a block or HMO, or a homeowner after building work. We adjust access, timing and paperwork to suit whoever commissions the work.

From enquiry to handover in Eltham

  1. Survey opening width, use and traffic
  2. Select pair configuration and hardware set
  3. Order certified doorset with coordinator and bolts if needed
  4. Install frame and hang both leaves
  5. Set closing sequence, seals and latching
  6. Test hold-open release and record evidence

Guide prices in Eltham

If you need a budget figure first, the guide for double fire doors is £1,600–£3,400 per pair supplied and fitted, depending on glazing and hardware, ex VAT. We firm that up after a survey, pricing each door separately so you can see where the money goes.

Around Eltham

Neighbouring towns such as Blackheath, Welling, Catford and Greenwich are covered too, so clients with several buildings can use one installer and one evidence format.

Common questions

Do you work in Eltham?

Yes, we take on double fire doors in Eltham and the surrounding area, including Blackheath and Welling. Send your postcode and a few details and we'll come back with survey dates.

Can you work from an existing inspection report for my Eltham building?

Yes. Send it over and we can often price straight from it, then confirm on site. We report back against the same door references so you can close actions off.

Do both leaves need closers?

Usually, yes. Each leaf of a fire door pair needs to close itself. The closers are sized to each leaf's width and weight.

Why does the gap between the two leaves matter?

The meeting edges are where flame and smoke can pass most easily. The gap and the seals there must match the certification for the pair to perform as tested.

Book a free survey in Eltham

Tell us about the doors and we will come back with survey dates and a fixed written quote.

CallGet a quote