Fire door supply and fitting in England, Wales, Scotland and Northern Ireland sales@firedoor-installation.comGuide prices
Fire Door Installation

Double fire doors in Dagenham, RM10

Pairs and leaf-and-a-half doorsets with meeting-edge seals, coordinators and flush bolts. Covering Dagenham and RM10, with a free survey and fixed written quote.

Quote in Dagenham

Free survey and a fixed written quote.

Prefer to talk? Call 0800 088 6248.

Double fire doors: our service in Dagenham

Our double fire doors service covers Dagenham and the wider Greater London area. Every job starts with a survey of the openings, so the quote reflects your actual doors rather than a guess.

Fire doors in Dagenham protect escape routes in mixed-use office buildings, clinics and schools alike. We adapt the programme to the building and its occupants, never the standard of the installation.

Every pair we fit in Dagenham is commissioned so both leaves close in the right order and latch. Leaf-and-a-half doors are a practical option for Dagenham care homes and schools that need occasional wide access.

Leaf-and-a-half for wider routes

Leaf-and-a-half doors give a usable everyday opening through the main leaf, with the smaller leaf opened for beds, trolleys or deliveries. They are common in care homes, hospitals and schools. The smaller leaf may be held with flush bolts; any bolts and their positions must be covered by the evidence.

As standard, the work covers:

  • Meeting-stile intumescent and smoke seals
  • Door coordinators where meeting edges are rebated
  • Flush bolts and hold-opens within evidence
  • Commissioning of closing sequence

What the rules say for Dagenham

The rules that apply to fire doors in Dagenham are England's. The responsible person under the Regulatory Reform (Fire Safety) Order 2005 must keep fire doors in non-domestic premises and the common parts of flats in working order; the Fire Safety Act 2021 confirmed that this includes flat entrance doors onto common parts. Enforcement of fire safety law in Dagenham sits with the London Fire Brigade.

Where a Dagenham block is above 11 metres, regulation 10 of the 2022 regulations means communal doors are checked every three months and flat entrance doors annually on a best-endeavours basis. Replacement doors must also satisfy the Building Regulations, with Approved Document B as the guidance most building control bodies work from.

Which buildings in Dagenham need double fire doors?

The need for double fire doors usually arises in schools or communal corridors, and sometimes hospitals and clinics. Each has its own pressures, such as residents at home or a building that must stay open, so we plan the sequence of work in Dagenham to keep escape routes protected throughout.

Our process in Dagenham

  1. Survey opening width, use and traffic
  2. Select pair configuration and hardware set
  3. Order certified doorset with coordinator and bolts if needed
  4. Install frame and hang both leaves
  5. Set closing sequence, seals and latching
  6. Test hold-open release and record evidence

What does double fire doors cost in Dagenham?

If you need a budget figure first, the guide for double fire doors is £1,600–£3,400 per pair supplied and fitted, depending on glazing and hardware, ex VAT. We firm that up after a survey, pricing each door separately so you can see where the money goes.

Covering Dagenham and nearby

Neighbouring towns such as Becontree, Romford, Hornchurch and Barking are covered too, so clients with several buildings can use one installer and one evidence format.

Common questions

Is Dagenham within your coverage area?

It is. We cover Dagenham in Greater London and neighbouring towns such as Becontree. There is no charge for the survey.

What happens on a survey in Dagenham?

We look at every door in scope: the leaf, frame, gaps, seals, hinges, closer, glazing and how the frame is fixed. You then get a written quote that prices each door separately.

Do both leaves need closers?

Usually, yes. Each leaf of a fire door pair needs to close itself. The closers are sized to each leaf's width and weight.

Why does the gap between the two leaves matter?

The meeting edges are where flame and smoke can pass most easily. The gap and the seals there must match the certification for the pair to perform as tested.

Talk to us about Dagenham

Tell us about the doors and we will come back with survey dates and a fixed written quote.

CallGet a quote