Fire door supply and fitting in England, Wales, Scotland and Northern Ireland sales@firedoor-installation.comGuide prices
Fire Door Installation

Double fire doors in Maidenhead, SL6

Pairs and leaf-and-a-half doorsets with meeting-edge seals, coordinators and flush bolts. Free survey in Maidenhead and door-by-door pricing.

Quote in Maidenhead

Free survey and a fixed written quote.

Prefer to talk? Call 0800 088 6248.

Double fire doors for Maidenhead buildings

For property owners, landlords and managing agents in Maidenhead, we offer double fire doors with one team for the survey, the product and the installation.

Maidenhead has a broad mix of buildings, including schools, HMOs and care homes, and the same fire door principles apply to all of them.

Double doors on wards, school corridors and lobbies in Maidenhead take heavy use, so closing sequence and meeting-edge seals get extra attention. Leaf-and-a-half doors are a practical option for Maidenhead care homes and schools that need occasional wide access.

Leaf-and-a-half for wider routes

Leaf-and-a-half doors give a usable everyday opening through the main leaf, with the smaller leaf opened for beds, trolleys or deliveries. They are common in care homes, hospitals and schools. The smaller leaf may be held with flush bolts; any bolts and their positions must be covered by the evidence.

On a typical job that means:

  • Closers matched to each leaf
  • Meeting-stile intumescent and smoke seals
  • Commissioning of closing sequence
  • Door coordinators where meeting edges are rebated

Rules and responsibilities in Maidenhead

Fire doors in Maidenhead fall under English rules. New and replacement doors are covered by the Building Regulations 2010 and Approved Document B. In workplaces and the common parts of blocks, the Regulatory Reform (Fire Safety) Order 2005, as clarified by the Fire Safety Act 2021, puts the duty on the responsible person to keep fire doors suitable and maintained.

For residential buildings in Maidenhead above 11 metres, regulation 10 of the Fire Safety (England) Regulations 2022 adds checks: communal fire doors at least every three months and best-endeavours checks of flat entrance doors at least every twelve months. Higher-risk buildings of at least 18 metres or seven storeys also come under the Building Safety Act 2022, where works may need approval from the Building Safety Regulator.

Where double fire doors fit in Maidenhead

From office cores to schools, the requirement for double fire doors in Maidenhead comes from the fire strategy or risk assessment for the building. We work from that document, or help you interpret your inspection report, before quoting.

The steps on a Maidenhead installation

  1. Survey opening width, use and traffic
  2. Select pair configuration and hardware set
  3. Order certified doorset with coordinator and bolts if needed
  4. Install frame and hang both leaves
  5. Set closing sequence, seals and latching
  6. Test hold-open release and record evidence

Budgeting for double fire doors in Maidenhead

If you need a budget figure first, the guide for double fire doors is £1,600–£3,400 per pair supplied and fitted, depending on glazing and hardware, ex VAT. We firm that up after a survey, pricing each door separately so you can see where the money goes.

Nearby areas we cover from Maidenhead

Maidenhead is about 18.9 km from Reading, and we cover both, along with nearby Slough and Windsor. Send us your postcode and we'll confirm survey dates.

Questions from Maidenhead

Do you work in Maidenhead?

Yes, we take on double fire doors in Maidenhead and the surrounding area, including Slough and Windsor. Send your postcode and a few details and we'll come back with survey dates.

What happens on a survey in Maidenhead?

We look at every door in scope: the leaf, frame, gaps, seals, hinges, closer, glazing and how the frame is fixed. You then get a written quote that prices each door separately.

What does a door coordinator do?

It holds the leaf that must close second until the first leaf has shut, so rebated meeting edges close in the right order and both leaves latch. Without it, the pair can end up open or misaligned.

Why does the gap between the two leaves matter?

The meeting edges are where flame and smoke can pass most easily. The gap and the seals there must match the certification for the pair to perform as tested.

Talk to us about Maidenhead

Tell us about the doors and we will come back with survey dates and a fixed written quote.

CallGet a quote