Fire doors fitted across Greater London
We provide fire door installation across Greater London, covering 82 towns and 279 postcode districts, including London, Islington and City of Westminster.
Wherever your building is in Greater London, the fire safety duties come from national rules, and our installation standard is the same.
The law behind fire doors in Greater London
The rules that apply to fire doors in Greater London are England's. The responsible person under the Regulatory Reform (Fire Safety) Order 2005 must keep fire doors in non-domestic premises and the common parts of flats in working order; the Fire Safety Act 2021 confirmed that this includes flat entrance doors onto common parts. Enforcement of fire safety law in Greater London sits with the London Fire Brigade.
Where a Greater London block is above 11 metres, regulation 10 of the 2022 regulations means communal doors are checked every three months and flat entrance doors annually on a best-endeavours basis. Replacement doors must also satisfy the Building Regulations, with Approved Document B as the guidance most building control bodies work from.
Services available in Greater London
Every service below is available across Greater London. Choose one for local details, or use the form to describe what you need.
- FD30 fire doors
- FD60 fire doors
- Certified fire doorsets
- Flat entrance fire doors
- Communal fire doors
- Composite fire doors
- Glazed fire doors
- Double fire doors
- Steel fire doors
- Fire exit doors
- Riser and cupboard fire doors
- Integral garage fire doors
- Loft conversion fire doors
- HMO fire doors
- Commercial fire doors
- Fire door replacement
- Fire door repairs and remedial works
- Fire door frames
- Intumescent strips and smoke seals
- Fire door closers
- Fire door ironmongery
- Fire door hold-open devices
Fire doors in Greater London: questions
Do you cover all of Greater London?
Yes. We work throughout Greater London, including London, Islington and City of Westminster. The survey and written quote are free.
Which fire door rules apply in Greater London?
English rules: the Building Regulations with Approved Document B, the Fire Safety Order 2005 and, for residential buildings above 11 metres, regulation 10 of the Fire Safety (England) Regulations 2022.
Do I need to be there for the survey?
Someone needs to give us access to the doors. For blocks and commercial buildings, a caretaker or site contact is fine; for HMOs and homes, we agree a time with you or your tenants.