Fire door supply and fitting in England, Wales, Scotland and Northern Ireland sales@firedoor-installation.comGuide prices
Fire Door Installation

Double fire door installation in Birkenhead

Surveyed, supplied and fitted in Birkenhead. Pairs and leaf-and-a-half doorsets with meeting-edge seals, coordinators and flush bolts.

Quote in Birkenhead

Free survey and a fixed written quote.

Prefer to talk? Call 0800 088 6248.

Getting double fire doors right in Birkenhead

If you need double fire doors in Birkenhead, we can survey, supply and install, then leave you the evidence your fire risk assessor will ask for.

Fire doors in Birkenhead protect escape routes in converted flats, mixed-use office buildings and restaurants alike. We adapt the programme to the building and its occupants, never the standard of the installation.

Double doors on wards, school corridors and lobbies in Birkenhead take heavy use, so closing sequence and meeting-edge seals get extra attention. Every pair we fit in Birkenhead is commissioned so both leaves close in the right order and latch.

Why pairs need extra care

The meeting stiles are the weak point of a pair. Gaps there must be controlled, both leaves need intumescent and smoke seals as specified, and if the meeting edges are rebated, a door coordinator is usually needed so the leaves close in the right order. If they close out of sequence, the door may not latch and will not perform as tested.

What you get:

  • Door coordinators where meeting edges are rebated
  • Flush bolts and hold-opens within evidence
  • Commissioning of closing sequence
  • Equal pair or leaf-and-a-half doorsets

Fire door law for Birkenhead properties

In Birkenhead, as elsewhere in England, the starting point is the Fire Safety Order 2005: whoever controls a workplace or the shared parts of a residential block must make sure its fire doors work. When doors are replaced, the Building Regulations and Approved Document B set the standard the new work has to meet.

Blocks above 11 metres have a specific routine under regulation 10 of the Fire Safety (England) Regulations 2022: quarterly checks of communal fire doors and annual best-endeavours checks of flat front doors. If your Birkenhead building is a higher-risk building under the Building Safety Act 2022, we confirm the approval route with the Principal Accountable Person before any work is ordered.

Buildings and duty holders in Birkenhead

Landlords, managing agents, facilities teams and homeowners in Birkenhead can all commission double fire doors from us. The usual settings are schools and care homes, though single doors for office cores are just as welcome.

The steps on a Birkenhead installation

  1. Survey opening width, use and traffic
  2. Select pair configuration and hardware set
  3. Order certified doorset with coordinator and bolts if needed
  4. Install frame and hang both leaves
  5. Set closing sequence, seals and latching
  6. Test hold-open release and record evidence

Budgeting for double fire doors in Birkenhead

Guide pricing for double fire doors: £1,600–£3,400 per pair supplied and fitted, depending on glazing and hardware, ex VAT. Volume work across several doors in one Birkenhead building usually brings the per-door cost down. Your written quote is fixed once we have surveyed.

Covering Birkenhead and nearby

Nearby towns we cover include Liverpool, Wallasey and Bebington. Distance from Birkenhead does not change our guide prices, and the survey and quote are free.

Questions from Birkenhead

Is Birkenhead within your coverage area?

It is. We cover Birkenhead in Merseyside and neighbouring towns such as Liverpool. There is no charge for the survey.

What happens on a survey in Birkenhead?

We look at every door in scope: the leaf, frame, gaps, seals, hinges, closer, glazing and how the frame is fixed. You then get a written quote that prices each door separately.

What does a door coordinator do?

It holds the leaf that must close second until the first leaf has shut, so rebated meeting edges close in the right order and both leaves latch. Without it, the pair can end up open or misaligned.

Do both leaves need closers?

Usually, yes. Each leaf of a fire door pair needs to close itself. The closers are sized to each leaf's width and weight.

Book a free survey in Birkenhead

Tell us about the doors and we will come back with survey dates and a fixed written quote.

CallGet a quote